K9302 MIO EPOXY MID-COAT
Product description:
This product is a high-performance two-component epoxy intermediate coating. The main components are epoxy resin, curing agent, and micaceous iron oxide (MIO) pigment. The special lamellar structure of micaceous iron oxide provides excellent barrier properties, preventing the penetration of water, oxygen, and corrosive ions into the coating film, thereby enhancing its corrosion resistance. It is specifically designed to serve as an intermediate protective layer in multi-coat systems, offering outstanding barrier protection and extending the service life of the entire coating system. It is an indispensable mid-coat in heavy-duty anti-corrosion coating systems.
Features:
1. Excellent anti-corrosion performance: The lamellar structure of micaceous iron oxide forms a dense and stable barrier film that effectively isolates corrosive substances, greatly extending the service life of metal substrates.
2. Outstanding adhesion: Provides strong adhesion to both primer layers (such as epoxy zinc-rich primers) and topcoats, forming a durable coating system with excellent interlayer bonding.
3. Excellent mechanical properties: The coating film is tough and durable, with excellent impact and abrasion resistance, maintaining integrity under mechanical stress.
4. High chemical resistance: Although primarily used as an intermediate layer, it offers sufficient resistance to chemicals and moisture, providing reliable protection for the coating system.
5. Easy application: Being a two-component system, it is easy to mix and apply, suitable for various application methods such as airless spray, air spray, or brush.
Recommended use:
This product is mainly used in heavy-duty anti-corrosion areas that require long-term protection and serves as an intermediate coat in anti-corrosion coating systems. The main applications include:
1. Bridge steel structures and buildings: Provides effective corrosion protection for large steel structures, steel plants, and steel towers.
2. Petrochemical facilities: Suitable for use in refineries, chemical plants, and power generation facilities, including storage tanks, pipelines, and related equipment.
3. Marine and offshore structures: Can be used on ship superstructures, docks, and offshore platforms.
4. Mechanical and engineering equipment: Provides anti-corrosion protection for construction machinery, cranes, and related equipment.
Product properties:
Viscosity: 130 ± 5 KU (25℃)
Specific gravity (g/ml): 1.47 ± 0.1 (g/ml)
Volume Solids (%): 70 ± 1%
Color: Iron Oxide Red
Mixing Ratio (by weight): A : B = 6:1
Recommended Thinner: DR100
Tool Cleaning Thinner: (Not included in the package)

Application Methods: Airless spray, air spray, brush, roller.
Recommended Coating Layers: 1 layer
Drying Time:
|
Hour (H), Day (D), Month (M)
|
30oC
|
|
Set to touch
|
2/3H
|
|
Hard Dry
|
12H
|
|
Recoat (Minimum)
|
18H
|
|
Recoat (Maximum)
|
4M
|
|
Pot life
|
8H
|
Drying time varies depending on film thickness and ambient temperature
Theoretical Coverage:
Approx. 5 m²/L/coat (Dry film thickness: 140 µm per coat)
Actual coverage may vary depending on application method, surface roughness (Rz), and material loss.
Coating System:
|
Product Name
|
Recommended Number of Coats
|
Recommended Dry Film Thickness
|
|
960PR Zinc Epoxy Primer
|
1 coat
|
75 μm
|
|
K9302 Mio Epoxy Mid-coat
|
1 coat
|
100-150 μm
|
|
MA366 Two-component Polyurethane Topcoat
|
1-2 coats
|
50-100 μm
|
Instructions for Use:
Surface Preparation Requirements:
1. Remove all visible grease, oil, lubricants, cutting fluids, and other soluble contaminants from the metal surface using solvents or other appropriate methods.
2. Follow SSPC-SP1 surface preparation standards before applying protective coatings.
3. Steel surfaces should be blast-cleaned to Sa2.5 (near-white metal blast) or SSPC-SP10 standards.
4. At least 95% of the surface area should be free of visible grease, oil, dirt, mill scale, rust, oxides, corrosion products, and other foreign matter.
5. Surface roughness should be within Rz 30–75 μm.
6. Power tool cleaning should reach St3 or above.
7. Loose or peeling coatings, rust, oxides, mill scale, and old paint must be removed with tools (e.g., power wire brushes, grinders, sanding belts) until solid metal is exposed with a metallic sheen.
8. Some minor rust stains may remain, but these can usually be addressed by the adhesion and protective performance of the primer. Whenever possible, defects should be removed or repaired.
9. Surface defects (e.g., weld spatter, burrs, cracks, holes) that affect coating adhesion and protection should be repaired before painting.
10. The surface must be free of grease, dust, dirt, mill scale, rust, oxides, corrosion, old coatings, burrs, and other contaminants before application.
11. If different coating systems have varying preparation requirements, please consult with our technical specialists before use.
Environmental Requirements for Application:
1. Temperature: Apply within the recommended range; do not apply below 5℃ or above 40℃.
2. Humidity: Relative humidity should not exceed 85%. Avoid application during rainy weather.
3. Ventilation: Ensure adequate ventilation for indoor applications. Avoid painting during strong winds outdoors.
4. Surface Temperature: Steel surface temperature must be at least 3℃ above the dew point to prevent condensation.
Storage:
Shelf Life: 2 year.
This product should be stored in a sealed container in a cool, dry, and well-ventilated area, away from direct sunlight and heat sources. Keep away from fire.
Precautions:
Carefully read the product’s application instructions before use.
The coating components must be thoroughly mixed and evenly stirred.
Thinning should follow the recommended dilution ratio specified in the instructions — do not over-dilute.
The mixing ratio between the base and hardener must strictly follow the specified proportions.
Keep away from sparks, flames, and high heat sources.
Ensure good ventilation at the application site. Workers should wear appropriate protective clothing, gloves, and eye protection. Refer to the Safety Data Sheet (SDS) for more information.
Any unused main agent and hardener should be stored separately in sealed containers and kept in a cool, dry place.
Packaging Specifications:
|
Packing:
|
|
|
16L
|
|
Packing:
|
|
|
3.2L
|
Safety Instructions:
1. Maintain good ventilation during application and keep the paint away from direct sunlight and heat sources.
2. To avoid contact with skin and eyes or inhalation of excessive paint mist, use protective equipment such as a mask and gloves.
3. If contact with eyes occurs, rinse immediately with plenty of water and seek medical attention. Keep out of reach of children.
4. Keep out of reach of children.
Disclaimer:
The above information represents typical properties, characteristics, and applications of the product and is provided as a guide only. It should not be construed as a product warranty, a statement that would create legal liability for the company, or a basis for assuming liability on the part of the company. It is the user's responsibility to verify the suitability of any batch of product for a specific application before use.