CLEANPOXY ANTI-STATIC LINING
Product description:
Cleanpoxy Anti-Static Lining is a two-component topcoat, high-solids, solvent-free modified epoxy self-leveling coating, specially developed for cleanrooms in high-precision industries and areas prone to static electricity accumulation and electrostatic discharge hazards. It provides an excellent and stable anti-static (ESD) conductive network performance. The coating offers excellent self-leveling properties and allows thick-film application in a single coat. After curing, it forms a flat, smooth, dense and compact surface. It is a high-performance anti-static epoxy topcoat specifically designed for concrete flooring.
Features:
1. The cured coating exhibits excellent physical and chemical properties.
2. Excellent chemical resistance.
Recommended use:
1. Cleanroom floors in semiconductor, electronics, optoelectronics, and precision instrument manufacturing facilities.
2. Floors of warehouses storing flammable and explosive chemicals.
3. Electrostatic discharge (ESD) work areas with high safety and protection requirements.
4. Computer room/server room flooring.
Product properties:

Drying Time:

Remarks:
If the maximum overcoating interval is exceeded, the surface activity of the coating film will decrease, resulting in poor intercoat adhesion. In such cases, the surface must be treated by sanding or sandblasting, and adequate adhesion strength must be confirmed before applying the subsequent coat.
Instructions for Use:
Surface Preparation
1. Concrete Curing Conditions:
Newly constructed concrete must be cured for at least 28 days under conditions of 21°C and 50% relative humidity (RH).
2. Physical and Chemical Requirements of the Substrate:
Concrete moisture content: ≤ 6%.
Concrete pH value: 7–9.
Concrete compressive strength: Minimum 160 kgf/cm².
If the concrete strength exceeds 260 kgf/cm², conventional floor grinding machines may have difficulty achieving sufficient surface roughness. In such cases, shot blasting or sandblasting must be used to create adequate mechanical anchoring points.
3. Cleaning and Surface Treatment:
Thoroughly remove oil, grease, moisture, mud, sand, dust, laitance, and other contaminants from the substrate surface. Ensure that the floor is smooth, clean, and dry.
4. Reinforcement of Poor-Quality Substrates:
If the concrete substrate is loose, porous, or has excessively high water absorption, apply a sealing and reinforcing primer to ensure adequate adhesion of the coating system.
5. Treatment of Cracks and Joints:
Cracks and cavities must be V-cut, then filled with epoxy repair putty and sanded smooth. For severe cracks, use epoxy mortar for repair. After completion of the coating application, expansion joints must be re-cut and filled with a suitable elastic joint sealant.
Application Environment and Methods:
Application Environment Requirements:
1. Ambient temperature: 5–35°C.
2. Substrate surface temperature: ≤ 40°C and must be at least 3°C above the ambient dew point temperature to prevent condensation.
3. Relative humidity: ≤ 85% RH.
4. Outdoor warning: This product is an epoxy resin system and is strictly prohibited for use in outdoor exposed environments. Exposure to solar UV radiation may cause discoloration and chalking.
Mixing and Agitation:
1. Accurately weigh the components according to the specified weight ratio: Main Component : Curing Agent = 4.5 : 1.
2. Use an electric mixer with a power rating of at least 300 W and a rotational speed of 1,000 RPM for mechanical mixing. Mix thoroughly for 3–5 minutes until completely homogeneous. Manual mixing is strictly prohibited, as it may result in localized areas of incomplete curing.
3. Exothermic Reaction Warning: After mixing, the solvent-free epoxy resin undergoes a strong exothermic cross-linking reaction. After mixing, do not leave the material in the mixing container, as heat accumulation inside the container will cause the Pot Life to decrease rapidly and may even result in excessive heat generation, creating a burn hazard. Immediately pour the mixed material onto the floor and spread it out.
Application Method and Defoaming:
1. Use a Notched Squeegee, rubber squeegee, rake, or trowel to spread and apply the coating evenly.
2. Scraping Coat / Sand-Embedded Sealing Coat: To prevent air released from concrete pores from causing pinholes and blistering in the topcoat, after completion of the primer application, apply a scraping and leveling sealing coat approximately 0.5–0.8 mm thick to seal the capillary pores.
3. Defoaming: After spreading, use a Spike Roller to roll back and forth over the coating to force the release and removal of residual air bubbles that cannot be eliminated naturally.
Recommended Coating System:
|
Paint systems
|
Recommended Product
|
Description
|
|
Primer
|
Cleanpoxy Primer
|
Seals concrete capillary pores and improves substrate adhesion
|
|
Intermediate Coat
|
Cleanpoxy Anti-Static Lining
+ Aggregate
|
0.5–0.8 mm thick layer for sealing capillary pores and leveling the surface
|
|
Topcoat
|
Cleanpoxy Anti-Static Lining
|
1.0–2.0 mm designed thickness anti-static self-leveling layer
|
|
Special Topcoat (Optional)
|
DHDC-9600 Anti-Static Coating
|
Used when additional wear resistance or special performance properties are required
|
Storage:
Shelf life: 6 months
This product should be stored in a cool, dry and ventilated place, away from direct sunlight and fire
Precautions:
Precautions for Coating Film and Anti-Static Performance:
1.Film Thickness Control: If the dry film thickness (DFT) is below 1.0 mm, the continuity of the anti-static conductive network may be insufficient, causing the surface resistance to exceed the specified upper limit. Surface flatness and overall appearance may also be reduced.
2.Temperature, Humidity and Amine Blushing: When curing under low temperatures (below 10°C) or high-humidity conditions, resin drying is delayed and the coating may readily absorb moisture and carbon dioxide (CO₂) from the air, resulting in Amine Blushing. This may cause surface whitening, tackiness, and loss of gloss. During application and curing, washing with water or allowing the coating to come into contact with water is strictly prohibited.
3.Floating/Color Variation of Conductive Material: This product contains specialized conductive additives for anti-static applications. If slight whitening or uneven coloration appears on the surface after application, this is a normal physical phenomenon caused by the distribution of conductive particles. It does not affect the overall anti-static performance or mechanical strength of the coating.
4.Cleanroom Silicone Contamination Warning: Residual silicone sealant from cleanroom partition installation may cause cratering/shrinkage and poor leveling of the coating film. All silicone must be completely removed and the surface properly treated before applying repair putty and the topcoat.
Packaging Specifications:
|
Set:
|
22KG
|
|
Component (A):
|
18KG
|
|
Hardener (B):
|
4KG
|
Safety Precautions:
Safe use of this product is essential for protecting the health and safety of application personnel and end users. Please carefully read the following safety precautions and strictly comply with all applicable requirements during application:
1. Before use, ensure that there are no open flames or sources of ignition at the application site, as this product contains flammable solvents that may ignite when exposed to fire or ignition sources.
2. If the product comes into contact with the skin or eyes, immediately rinse thoroughly with plenty of clean water and seek medical attention if necessary.
3. Do not mix this product with other chemical products unless compatibility has been confirmed, in order to avoid chemical reactions that may result in unpredictable accidents.
4. Store the product in a cool, dry, and well-ventilated area, away from direct sunlight and high temperatures.
5. In case of improper handling or accidental ingestion, contact the local emergency medical center as soon as possible and bring the product label or product information to the medical facility for reference.
Safety Warning: When using this product, appropriate personal protective equipment (PPE) must be worn, including protective gloves, safety goggles, a suitable respirator/mask, and protective work clothing. Avoid direct inhalation of spray mist, solvent vapors, and other volatile substances during application, and ensure adequate ventilation at all times.
Note: The original text states that this product complies with relevant safety requirements of ISO (International Organization for Standardization) and ASTM (ASTM International). Such a statement should only be included in the official TDS/SDS if the manufacturer has specific documentation demonstrating compliance with the applicable ISO/ASTM standards. ISO and ASTM are not, by themselves, general safety certifications for an entire product.
Disclaimer:
The above information represents typical properties, characteristics, and applications of the product and is provided as a guide only. It should not be construed as a product warranty, a statement that would create legal liability for the company, or a basis for assuming liability on the part of the company. It is the user's responsibility to verify the suitability of any batch of product for a specific application before use.
Technical Data Sheet for Cleanpoxy / Version 1.0/ Date of last alteration: 2026/08/17
© Copyright NOROO-NANPAO, All rights reserved
® NOROO-NANPAO giữ bản quyền nội dung trên website này